FEMA has recently introduced new mapping all across the Country and changed some of their designations. The important thing about V-Zones is that FEMA designates an elevation on their maps that homes have to be elevated above. The V-Zone is part of areas subject to wave heights in excess of 3 feet or high velocity wave action and erosion and wave born debris. The designation doesn't carry landward very far before the designation changes. Here it would be along the Pacific Ocean. The "V-Zone" is FEMA's velocity zone typically adjacent to a large body of open water and is one designation in coastal high-hazard areas. There other requirements that you might find pertinent. high water mark or an equivalent benchmark based on seasonal or storm-driven flooding from the authority having jurisdiction. All electrical connections not intended for operation while submerged shall be located at least 300 mm (12 in.) above the deck of a floating orįixed structure, but not below the electrical datum plane. Service equipment shall disconnect when the water level reaches the height of the established electrical datum plane.Ħ82.12 Electrical Connections. On land, the service equipment for floating structures and submersible electrical equipment shall be located no closer than 1.5 m (5 ft) horizontally from the shoreline and live parts shall be elevated a minimum of 300 mm (12 in.) above the electrical datum plane. Portion of an enclosure for electrical equipment not identified for operation while submerged shall be located below the electrical datum plane.Ħ82.11 Location of Service Equipment. Electrical equipment and transformers, including their enclosures, shall be specifically approved for the intended location. (3) In land areas subject to flooding, the electrical datum plane based on (1) or (2) above is a horizontal plane 600 mm (2 ft) above the point identified as the prevailingĦ82.10 Electrical Equipment and Transformers. (2) In land areas not subject to tidal fluctuation, the electrical datum plane is a horizontal plane 600 mm (2 ft) above the highest water level for the area occurring (1) In land areas subject to tidal fluctuation, the electrical datum plane is a horizontal plane 600 mm (2 ft) above the highest tide level for the area occurring under normalĬircumstances, that is, highest high tide. The electrical datum plane as used in this article is defined as follows: The only thing I Know of in the NEC is in ARTICLE 682- NATURAL AND ARTIFICIALLY MADE BODIES OF WATER which defines the datum plain as listed belowĮlectrical Datum Plane.















Sanitary on piles breakaway walls